Weekly Progress

Week 1.  Group formation and brief idea about requirements of the project " Design of a new Femur Bone".


Week 2.  Design proposal submission and basically we started the lab with derivation of measuring bending stiffness of bone. And plotting in MATLAB for estimating force based on geometry, modulus and a given displacement.



“Design of New Femur”

Project Design Proposal


Date Submitted: April 10, 2013


Submitted to:
Dr. Joseph J. Sarver, j.sarver@drexel.edu
Group Members:
Adam Smith, ams645@drexel.edu
Harsh Patel, hap38@drexel.edu
Yi Yu, yy374@drexel.edu





Abstract:

The Purpose of this project is to design a diseased mouse femur bone which is mechanical in nature and yet will be strong. The goals for this project are to create a mechanical design by analyzing CT scans of a mouse femur. Knowing the acceptable size of the femur bone will allow the design to be drawn in AutoCAD. From AutoCAD, the file can be imported into the Rapid Prototyping Machine and printed three dimensionally. Based on this new design of femur bone series of tests will be performed in lab for determining its strength and flexibility using the three point bending tests and bending equations. Also the new design of femur will be tested to different models of femur to determine the ratio of its mechanical strength over flexibility. The major tasks involved in this projects are mechanical CAD design, 3D models from rapid prototyping machine and testing. And at last the final deliverables for the project are a brief final report will be submitted and a powerpoint presentation on more detailed explanation with 3D models of the process involved to conclude which femur bone design is effective for the femur of a mouse.





1 Introduction




A diseased mouse femur bone will be designed, created, and tested. The goal is to create a prototype able to endure the same forces as a normally functioning mouse femur bone. The mechanical design must be functional in nature and yet still be strong. The strength of the bone will greaten as its size and weight increases. Unfortunately if the size is too great, the design will lose its practicality in nature. Thus, a balance between strength and functionality must be determined and applied. To discover the range in which the bone size is still considered practical, computer tomography scans, also known as CT Scans, will first be analyzed. Knowing the acceptable size range of the bone will allow a design functional in nature to be drawn in AutoCAD. From AutoCAD, the design will then be imported to Creo Parametric Software Design. Once imported, the model will be in the correct file needed to print the prototype three dimensionally with the rapid prototype machine. The three dimensional model of the bone will allow a series of tests to be done on the bone to determine its strength and flexibility. The first of these tests will be the three point bend test. This test applies a pressure to the center of an object held by two equidistant points from the middle of the object. The force needed to break the object is recorded. This force tells the strength and flexibility of the design with respect to other tested models. Once the initial bone has been tested, its design will be analyzed and modified to engineer a stronger femur.

By re-engineering a diseased mouse femur into a more functional one, a greater understanding of how a human bone replacement is designed. Uses of new machines will be discovered such as the Rapid Prototype Machine and the flexibility test machine. New tests and algorithms meant for analyzing the strength of a prototype will be used such as the three point bend test. A new thinking process that begins with research, followed by design and creation, and ending with testing and modification will be learned. This is a way of problem solving that any engineer will need to use in the field.

2 Deliverables





The first deliverable obtained will be the AutoCAD Design of the mouse femur. AutoCAD will be used because its file type, .stl, is compatible with the three dimensional printer [2]. The prototype will be scaled to the same dimensions of a natural mouse femur. The model will be scaled larger than the true size of a mouse because it would be difficult to three dimensionally print and test such a small object. To test the design, a prototype will need to be printed using the rapid prototyping machine. Instead of cutting an object to create a model, this machine layers material until the inputted design is made. A three point bend test will be done on the prototype to test it’s flexibility and strength. The test applies a load in the middle of an object until it’s point of failure [3]. Once the maximum load is determined, the Euler-Bernoulli equation will determine the bending moment and deflection of the object. The bending moment is the distance an object is displaced from an applied load. The deflection is the degree of the angle made in an object when it is bent [1]. The three point bend test will be done on several models of different femur designs. Two ratios will determine which bone design is the best model. The first ratio is the bending moment to the maximum load capacity. The second is the deflection to the maximum load capacity. These ratios will show the flexibility to strength of a design. A small ratio is desired because in nature bones are not meant to be flexible, but rather rigid. If a mouse’s bone were to be flexible, it would bend under the pressure applied by the mouse. The mouse, therefore, would not be as stable. To conclude the project, a final report will be given. The report will show the processes involved to conclude which bone design is the most effective for the femur of a mouse.

3 Technical Activities


3.1 Design of New Mouse Femur Bone


3.1.1 Design in AutoCAD

Design of the new femoral bone of a mouse will be made using CT scans of an actual 
mouse femur as a template.


3.1.2 Three Dimensional Printing



    Next importing the design of the new femur bone from Auto CAD into the Rapid 
prototyping machine. A three dimensional model will be created using the Rapid 
Prototyping Machine.

3.2 Testing of the Design


The next challenge of the project is to test the design which is mechanical in design. The Three Point Bend Test will be performed to determine the flexibility and strength of the design. The design will be tested for its mechanical nature by putting the load at its center until the point of its failure. And finally the design will be tested with the different femur designs to obtain the ratio of its mechanical strength to its flexibility.



3.3 Analysis of the Test

Once the Three Point Bend Test is administered, the test will be analyzed using Euler-Bernoulli’s Equation. The analysis will describe the bone’s flexibility.



4 Project Timeline


Week


















Task
1
2
3
4
5
6
7
8
9
10
Research
x
x
x
Mechanical design
x
x
x
x
x
x
Rapid prototyping 3D printing
x


x


x




Testing
x
x
x
x
x


Modification
x
x
x




Final report preparation
x
x
x
Table 1

Project Timeline Tasks
1. Research and Study
a) Research will begin with studying the true dimensions of both mutated and healthy femur bones. The dimensions of both types will be noted from CT scans. True dimensions will be needed to properly scale the prototype.
b) Researching how forces are distributed on the bone in nature will be done next. Knowing how the forces are distributed will give clues to how the bone should be modeled.
c) The natural flexibility of mouse femur bones will be studied to know how stiff the bone should be to properly support the body.
d) Rapid prototyping machine, three point bend tests, and bending equations will be researched to know how to properly test and analyze the femur bone.
2. Create CAD design using dimensions similar to a natural bone.
3. Sign up for Rapid Prototyping Machine.
4. Sign up for use of the Three Point Bend Test Machine.
5. Create the second CAD design.
6. Sign up for the Rapid Prototyping Machine.
7. Sign up for the Three Point Bend Test Machine.
8. Print the first design using the Rapid Prototyping Machine.
9. Test the first design using a Three Point Bend Test.
10. Analyze the Three Point Bend Test using bending equations and the Euler-Bernoulli equation.
11. Print the second design using the rapid prototyping machine.
12. Test the second design using a Three Point Bend Test.
13. Analyze the second Three Point Bend Test using bending equations and the Euler-Bernoulli equation.
14. Create the third CAD design modifying it from the first two designs.
15. Sign up for use of the Rapid Prototyping Machine.
16. Sign up for use of the Three Point Bend Test Machine
17. Analyze the results of the third Three Point Bend Test Machine using bending equations and the Euler-Bernoulli equation.
18. Preparation for the final report and presentation will be done. This will include a PowerPoint presentation with pictures and collected data from the analyzed tests.


5 Facilities and Resources
The resources needed to create a prototype of the mouse femur are the rapid prototyping machine and access to the materials testing lab. The rapid prototyping machine will create the three dimensional models of the mouse femur. These models will be tested in the materials testing lab. In the lab, a three point bend test will be administered on several different designs of the femur. Therefore, the three point bend testing machine will be needed.

6 Expertise



The skills required for this project are those concerning the computer software AutoCAD. The bone will need to be designed in three dimensional AutoCAD. Knowing how to import the design from AutoCAD to the Rapid Prototyping Machine will be needed. Also basic knowledge of using the rapid prototyping machine for printing 3D models using different plastic materials is required as a part of this project.


7 Works Cited


1. "Euler–Bernoulli Beam Theory." Wikipedia. Wikimedia Foundation, 04 Jan. 2013. Web. 09 Apr. 2013. <http://en.wikipedia.org/wiki/Euler–Bernoulli_beam_theory>.


2. "SRP Workflow." Subtractive Rapid Prototyping. Roland DGA Corporation, n.d. Web. 09 Apr. 2013. <http://www.rolanddga.com/solutions/rapidPrototyping/pg7.asp>.


3. "Three Point Bending Test." Http://me.yeditepe.edu.tr/. Yeditepe University Department of Mechanical Engineering, n.d. Web. 9 Apr. 2013. http://me.yeditepe.edu.tr/courses/me402/three%20point%20bending%20test.pdf.


Week 3:-

This week we started our lab by submitting our CREO part .stl file for 3D printing. Also we worked on converting the CT scan images of mouse femur to the .stl file in ITK Image Snap software so we can import it to the CREO software. And at the end of the lab we divided tasks to be performed for next week among our group members. Also we created few design of the femur bone from the CT Scan Images of diseased mouse femur bone.



                                                        1.Left Side View of Bone



                                                          2.Right Side View of Bone
                                                                

                                                          3. Top view of Bone



4.Bottom View of Bone



Week 4 :-

This week we strated our lab with modifying the design of the CT Scan images of mouse femur bone and also completed the Team work Assessment during this week. Also we send our file for the 3D printing to the rapid prototyping machine. Also we created the inside view of the femur bone using MiniMagics 2.0 software.


                                         1. Cross Section of front side of Bone



                                            2. Cross Section of back side of Bone


Week 5:-

During this week we received our redesigned printed bone with better strength and than we went to laboratory for testing of its length, strength, and bending stiffness and obtained the following results from testing.


                                               

                                                Figure:1 3D Printed redesigned Bone



                                     Figure:2 Measuring length of broken part of bone


                                               
                                                  Figure: 3 Measuring width of bone


                                   
                                     Figure:4 Bone breaks after applying tension of 5 N





                                         
                                               
                                        
                                                 
                                                   Figure:5 Measuring Length of bone

At the end of the lab we decided to make hollow bone model in CREO and send to 3D printer to perform test with acetone as the 3D printer plastic strength cannot be changed in order for printing a weaker bone so during week 7 we will be testing this hollow bone printed with ABS( Acrylonitrile Butadiene styrene) plastic which is completely soluble in acetone. Below is the graph of bending stiffness of femur bone[1] using Microsoft Excel.






Figure: 1 Bending Stiffness Graph of Normal Femur Bone 1

Week 6:-  

During this week lab we sent  two different designs of mouse femur bone for 3D printing one little thick and other one thin so we can perform testing in acetone between week 6 and week 7. Also we did testing with hollow bone and non hollow bone to determine its strength and stiffness compared to our design of bone[1].Below are the figures of broken parts of hollow bone[2] and non hollow bones[1] after performing test on it.







Figure:1 Bone with plastic inside (Non Hollow Bone)


  

                                                             Figure:2 Hollow Bone



Figure:3 (Top)  Thin bone and (Below) Thick Bone on which testing was done during this week


Also the graph of bending stiffness obtained from measurements and testing of bone in figure [3] is shown in figure[4].


Figure 4: A graph whose slope defines the bending stiffness for Thin Bone 1





Figure 5:A graph whose slope defines the bending stiffness of thick bone 1




 The pictures of bone after leaving in 100% acetone for approximately 3 hours.


                                      
                                        Figure 6: The bones gets thinner after leaving in acetone.



Figure 7:  bone prototype after leaving in acetone

Week 7:- During this week we submitted our draft final report and for the rest of the lab we worked on editing our report for final submission.

Week 8:- During this week we didn't received our modified bone sent for the 3D printing so we couldn't perform any testing. So, we worked on editing our Draft final report after getting comments from professor Dr. Sarver. And also from week 6 the bone we tested after leaving in acetone failed to break and that's the result why we need to send other bone parts so we can do testing during week 8.

Week 9:- During this week we finally got the bone part and then we soak it in the acetone for one hour and performed testing on it in the lab. And the bone looks like as shown in figure[8].
Figure :8 Performing test on acetone soaked bone


Figure:9 Performing test on acetone soaked bone

No comments: